Menü überspringen

IBV 6000 Series

Request

Documentation

undefinedProduct Information

Specifications

IBV 6072

IBV 6172

IBV 6272

Input

1 VPP

Electrical connection

M23 flange socket (female), 12-pin

Cable length

≤ 60 m at UP > 4.9 V

≤ 30 m at Iencoder ≤ 120 mA

Note the voltage supply range of the connected encoder

Interpolation1)

IBV 6072: 2-fold

IBV 6172: 2-fold (fixed), 5-fold, 10-fold (switchable)

IBV 6272: No interpolation (fixed), 5-fold, 10-fold (switchable), 20-fold, 25-fold, 50-fold, 100-fold (switchable)

Input frequency2) for interpolation

2-fold

500 kHz

5-fold

10-fold

200 kHz

200 kHz

200 kHz

100 kHz

133 kHz

66 kHz

100 kHz

50 kHz

80 kHz

40 kHz

50 kHz

25 kHz

25 kHz

12.5 kHz

20-fold

25-fold

50-fold

100-fold

100 kHz

80 kHz

40 kHz

20 kHz

50 kHz

40 kHz

20 kHz

10 kHz

33 kHz

26 kHz

13 kHz

6.6 kHz

25 kHz

20 kHz

10 kHz

5 kHz

20 kHz

16 kHz

8 kHz

4 kHz

12.5 kHz

10 kHz

5 kHz

2.5 kHz

6.25 kHz

5 kHz

2.5 kHz

1.25 kHz

Outputs

1 VPP and TTL (for possible combinations see Selecting the output signals)

The following specifications refer to TTL outputs

Electrical connection

Two M23 flange sockets (male), 12-pin

Cable length

≤ 100 m (Uas ≤ 50 m)

Edge separation a1)

≥ 0.150 µs

≥ 0.100 µs

≥ 0.220 µs

≥ 0.345 µs

≥ 0.465 µs

≥ 0.585 µs

≥ 0.950 µs

≥ 1.925 µs

Reference mark signal1)

Pulse width 90° elec. (not with IBV 6072) or 270° elec.

Fault indication1)

Through fault detection signal Uas or, in addition, Ua1/Ua2 high impedance

Voltage supply

5 V ± 0.25 V (only through X2)

Current consumption3)

IBV 6072: ≤ 60 mA

IBV 6172: ≤ 90 mA

IBV 6272: ≤ 130 mA

Operating temperature

Storage temperature

0 °C to 70 °C

–30 °C to 80 °C

Vibration 50 to 2 000 Hz

Shock 11 ms

≤ 10 m/s2

≤ 300 m/s2

Protection

IP 65

Weight

Approx. 0.7 kg

Bold: This version is the factory default setting

1) Adjustable

2) Adjustable; nominal value. The actual input frequency can be up to 5 % lower. Exceeding this limit results in failure.

3) Not including current consumption of the encoder or output load (80 mA with recommended input circuitry)