Scale |
LIC 4005 |
|||||
Measuring standard Coefficient of linear expansion |
Steel scale tape with absolute and incremental METALLUR track Depends on the mounting surface |
|||||
Accuracy grade |
±5 µm |
|||||
Baseline error |
≤ ±0.750 µm/50 mm (typical) |
|||||
Measuring length (ML)* |
140 240 340 440 540 640 740 840 940 1040 1140 1240 1340 1440 1540 1640 1740 1840 1940 2040 |
|||||
Greater measuring lengths of up to 28 440 mm with a single-section scale tape and individual scale carrier sections |
||||||
Mass Scale tape Parts kit Scale tape carrier |
31 g/m 80 g + n1) · 27 g 187 g/m |
|||||
Scanning head |
LIC 411 |
LIC 419 F |
LIC 419 M |
LIC 419 P |
LIC 419 Y |
|
Interface |
EnDat 2.2 |
Fanuc Serial Interface αi |
Mitsubishi high speed interface |
Panasonic Serial Interface |
Yaskawa Serial Interface |
|
Ordering designation* |
EnDat22 |
Fanuc05 |
Mit03-4 |
Mit02-2 |
Pana01 |
YEC07 |
Measuring step* (note measuring length limitation2)) |
0.01 µm (10 nm) 0.005 µm (5 nm) 0.001 µm (1 nm) |
|||||
Calculation time tcal Clock frequency |
≤ 5 µs ≤ 16 MHz |
– |
||||
Traversing speed3) |
≤ 600 m/min |
|||||
Interpolation error |
±20 nm |
|||||
Electrical connection* |
Cable, 1 m or 3 m, with 8-pin M12 coupling (male) or 15-pin D-sub connector (male) |
|||||
Cable length (with HEIDENHAIN cable) |
≤ 100 m |
≤ 50 m |
≤ 30 m |
≤ 50 m |
||
Supply voltage |
DC 3.6 V to 14 V |
|||||
Power consumption3) (max.) |
At 3.6 V: ≤ 700 mW At 14 V: ≤ 800 mW |
At 3.6 V: ≤ 850 mW At 14 V: ≤ 950 mW |
||||
Current consumption (typical) |
At 5 V: 75 mA |
At 5 V: 95 mA (without load) |
||||
Vibration 55 Hz to 2000 Hz Shock 6 ms |
≤ 500 m/s2 (EN 60068-2-6) ≤ 1000 m/s2 (EN 60068-2-27) |
|||||
Operating temperature |
–10 °C to 70 °C |
|||||
Mass Scanning head Connecting cable Connecting element |
≤ 18 g (without cable) 20 g/m M12 coupling: 15 g; D-sub connector: 32 g |
|||||
* Please select when ordering 1) n = 1 for ML 3140 mm to 5040 mm; n = 2 for ML 5140 mm to 7040 mm; etc.* 2) Mitsubishi: 1 nm: measuring length ≤ 2040 mm; 5 nm: measuring length ≤ 10 040 mm; 10 nm: measuring length ≤ 20 040 mm Yaskawa: 1 nm: measuring length ≤ 1840 mm; 5 nm: measuring length ≤ 9040 mm; 10 nm: measuring length ≤ 18 040 mm 3) See General electrical information in the Interfaces of HEIDENHAIN Encoders brochure |